Muffle
When it comes to creating a successful online presence for your laboratory business, having a well-structured and SEO-friendly website is key. One essential aspect of this is ensuring that your website strictly complies with WordPress SEO regulations and validations. By adhering to these best practices, you can improve your website’s search engine rankings, drive organic traffic, and ultimately, attract more potential customers to your laboratory equipment offerings.
A well-optimized website not only makes it easier for search engines to crawl and index your content but also enhances the overall user experience. This means that visitors to your site can quickly find the information they are looking for, leading to higher engagement and potentially more conversions. By focusing on WordPress SEO compliance, you can stay ahead of the competition in the highly competitive laboratory equipment market and position your business for long-term success.
MUFFLE KALSTEIN
At Kalstein you can find the ideal Muffle for Your Laboratory

Laboratory Muffle Furnace YR05284-1
Furnace Structure & Chamber: High purity fibrous alumina insulation for maximum energy saving 60-80% less power consumption than other old style. Heavy duty double ...

Universal Lab High Temp Box Muffle Furnace YR05272 // YR05284
YR series muffle furnace adopts box type structure, is more convenient to put and take material, and the max. temperature of the...
Our Muffle best seller
Can be customized according to your needs.
YR muffle furnace uses double carbon steel layer shell and 30 segement PID control. The furnace consists of high purity alumina polycrystalline fiber brick and high quality heating element. This furnace equips with air cooling system, which makes temperature cool and rise quickly. It is an ideal tool for materials annealing and sintering , composition analysis, quality testing, ashing in colleage lab, research institutes, etc..
Standard Features
- 1200°C,1400°C,1700°C maximum operating temperature;
- High purity fibrous alumina insulation for maximum energy saving;
- Double layer steel structure with air cooling fan to keep furnace’s exteriors safe to touch;
- Safty interlock will automatic power off the furnace when door is opened;
| Model | Chamber Size
( Dx Wx H) (cm) |
Capacity | Max. Temp | Continuous Working
Temperature |
Heather | Thermocouple | Working
Voltage |
Max.
Power |
Weight |
| YR05272 | 10x10x10 | 1 | 1200 | ≦1100°C | Fe-Cr-Al-Mo Wire | K type | 220-380V | 1-9KW | 70KG
11KG |
| YR05273 | 20x15x15 | 4,5 | 93kg | ||||||
| YR05274 | 30x20x12 | 7,2 | 84kg | ||||||
| YR05275 | 30x20x20 | 12 | 124kg | ||||||
| YR05276 | 40x30x30 | 36 | 178kg | ||||||
| YR05277 | 10x10x10 | 1 | 1400 | ≦1300°C | SiC heater | S typer | 1-16KW | 61kg | |
| YR05278 | 20x15x15 | 4,5 | 94kg | ||||||
| YR05279 | 30x20x20 | 12 | 127kg | ||||||
| YR05280 | 40x30x30 | 36 | 180kg | ||||||
| YR05281 | 10x10x10 | 1 | 1700 | ≦1600°C | MoSi2 heater | B type | 66kg | ||
| YR05282 | 20x15x15 | 4,5 | 136kg | ||||||
| YR05283 | 30x20x20 | 12 | 190kg | ||||||
| YR05284 | 40x30x30 | 36 | 310kg |
Analysis of the best Muffle for Your Laboratory

What advantages do Muffles offer in the Laboratory?
In many laboratories, the muffle furnace is used to heat materials to high temperatures. It is an enclosed air chamber that surrounds the material to be heated, the air is heat...

Scientific applications of laboratory Muffles for sample handling in pathology laboratories
Muffles are essential devices in laboratories, particularly in the field ...

What are the essential requirements for using a muffle in a laboratory environment
Muffle devices are a fundamental part of maintaining safety in industrial laboratories; these units control the mixi...

Implementation of muffles in the laboratory
The muffle is a equipment used for the smelting of metals and for the cooking of materials, by using thermal energy. They are made up of different elements, which a...
Catalog of models of Muffle on offer
KALSTEIN UPDATED
Guidelines for you to become an expert in Muffle
The Muffle equipment are essential products in Your Laboratory, we provide you with guidance and recommendations for a better use, so you can work like an expert.
How are Muffles used in the Laboratory? - KALSTEIN
Energy Efficiency in Laboratory Muffles: Recent Innovations
New Trends in Laboratory Muffles: Quality and Efficient Consumption
Cutting-Edge Muffle Furnaces for Precision Thermal Analysis
Frequently asked questions from our customers about Muffle
The delivery time of your Kalstein product will depend on the following:
- Whether the equipment you are interested in is in stock or if it needs to be manufactured.
- The type of freight you have chosen, which can be either air or sea.
- Equipment in stock:
– Delivery Time (Air): 15-30 days.
– Delivery Time (Sea): 45-60 days.
- Equipment not in stock:
– Delivery Time (Air): 30-60 days.
– Delivery Time (Sea): 60-90 days.
You can make your purchase through:
- By email: [email protected]
- By phone: +33 (0) 1 70 39 26 50
- Online shopping: Through the official Kalstein website in your country.
At Kalstein, we provide our customers with inductions and technical support through new online methods. You can visit our induction videos, technical assistance, and guidance provided by a Kalstein team through our Youtube channel (Kalstein English). HERE
Send us a direct message and one of our agents will contact you
Muffle
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Sed dignissim placerat mauris cursus laoreet. Nam feugiat lacus ex, at fermentum sapien accumsan nec. Curabitur auctor porttitor mi non malesuada. Aenean condimentum, purus vitae rhoncus imperdiet, justo eros aliquam ipsum, at egestas leo diam eget libero.
Catalog of models of Muffle on offer.
-
Biosafety cabin YR06543 // YR06547
This product has multiple variants. The options may be chosen on the product page -
Biological safety cabinet YR06538 // YR06542
This product has multiple variants. The options may be chosen on the product page -
Desktop Laminar Flow Cabinet YR06525//YR06528
This product has multiple variants. The options may be chosen on the product page -
Ductless Fume Hood YR06570
-
Desktop Ductless Fume Hood YR06569
-
Ductless fume hood YR06566 // YR06568
This product has multiple variants. The options may be chosen on the product page -
Desktop Ductless Fume Hood YR06563 // YR06565
This product has multiple variants. The options may be chosen on the product page -
Ductless fume hood YR06560 // YR06562
This product has multiple variants. The options may be chosen on the product page -
Desktop Ductless Fume Hood YR06557 // YR06559
This product has multiple variants. The options may be chosen on the product page -
Epoxy Coated Steel Chemical Laboratory Fume Hood YR06553 // YR06556
This product has multiple variants. The options may be chosen on the product page -
Pet Dryer with Stainless Steel YR06583 – YR06584
This product has multiple variants. The options may be chosen on the product page -
Small Pet Dryer All Steel YR06581-YR06582
This product has multiple variants. The options may be chosen on the product page -
Stainless Steel Pet Dryer YR06579 – YR06580
This product has multiple variants. The options may be chosen on the product page -
Pet Dryer Machine YR06577 – YR06578
This product has multiple variants. The options may be chosen on the product page -
Pet dryer machine all stainless Steel YR06575 – YR06576
This product has multiple variants. The options may be chosen on the product page -
Pet dryer machine stainless steel liner YR06573 – YR06574
This product has multiple variants. The options may be chosen on the product page
Descubre más de nuestro catálogo
Tipos de Muffle
[Producto] A
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
[Producto] B
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Find out more about Muffle with our guides.
Exploring the Impact of Various Exercise Regimens on Glucose Metabolism in Older Adults: A Comprehensive Review
Introduction Aging is often accompanied by a decline in skeletal muscle insulin sensitivity, abnormal fat distribution, and a gradual reduction...
Utilizing Metagenomic Sequencing to Diagnose Salmonella enterica-Induced Septic Arthritis in a Healthy Child: A Detailed Case Study
Introduction Septic arthritis caused by Salmonella enterica is a condition that typically affects children with underlying health issues such as...
Advanced Features in Commercial Gas Dryers: A Comparative Study
In the world of commercial drying equipment, two names stand out for their innovations: Kalstein and Maytag. Both brands offer...

