Description
The ATC Car Refractometers YR05916 // YR05930 are precision instruments designed for analyzing the concentration of ethylene glycol and propylene glycol-based cooling systems in vehicles. Equipped with an automatic temperature compensation (ATC) feature, these refractometers ensure accurate readings by automatically adjusting for temperature variations. Utilizing ambient light, they do not require batteries, making them convenient and user-friendly. These robust devices are also capable of measuring the freezing point of windshield cleaning fluid, adding versatility to their functionality.
Price in the Market
In the market for refractometers like the ATC Car Refractometers YR05916 // YR05930, you can expect to find a price range between $60 USD to $240 USD. This competitive pricing makes these high-quality refractometers an attractive option for both professionals and individuals looking to maintain their vehicle’s cooling and cleaning systems effectively.
Frequently Asked Questions
Q: Does the refractometer require a battery?
A: No, the refractometer uses ambient light and does not require any battery or external power source.
Q: Can this device be used for measuring other liquids?
A: While the primary purpose is for ethylene glycol and propylene glycol, it can also measure the freezing point of windshield cleaning fluids and other suitable liquids.
Advantages and Disadvantages
Advantages: The refractometers are easy to calibrate, have a durable construction, and are equipped with a rubber grip for comfortable use. The ATC feature ensures precise readings regardless of temperature changes.
Disadvantages: These devices might not be suitable for use in environments with extreme lighting conditions, as they rely solely on ambient light for operation.
Product Usage in the Field
In practical scenarios, these refractometers are utilized by automotive professionals for regular maintenance checks of vehicle cooling systems, ensuring that the concentration of antifreeze liquids is within optimal ranges to prevent engine overheating or freezing under extreme temperatures. They are a valuable tool for precision and reliability in vehicular fluid analysis.
Recommendations
For achieving the best results with your ATC Car Refractometer, calibrate the device using distilled water before first use and periodically as needed. Clean the prism and cover plate with a soft, lint-free cloth after each use to prevent residue buildup. Additionally, avoid exposing the refractometer to harsh conditions or dropping it to maintain its precision and longevity.
Features
- Durable pure aluminum body construction
- No need for batteries or external power sources
- Simple to focus and calibrate
- Equipped with an ATC function for automatic temperature compensation
- Cushioned with a non-slip rubber grip for comfortable handling
Technical Specifications
Model | Description | Measurement Range | Min. Div. | Accuracy | ATC | ATC Temp. | Material |
YR05916 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃, | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05917 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05918 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05919 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05920 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05921 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05922 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05923 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05924 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05925 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05926 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
YR05927 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
YR05928 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer |
Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05929 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer |
Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
YR05930 | RHA-801 ATC 0-40% Urea Concentration AD Blue Optical | 0%-40% Urea Concentration | 0.2%Urea Concentration | ±0.2%Urea Concentration | Yes | 10-30° C | Pure aluminium |