Description
The Doppler Fetal Monitor YR02180 is a cutting-edge device designed for use in both operating theaters and intensive care units. With its 17-inch LCD screen and semi-modular design, it offers comprehensive monitoring through six standard parameters: ECG, SpO2, TEMP, NIBP, RESP, and PR/HR. This monitor boasts both 5-lead and 3-lead ECG configurations, a method that ensures accurate cardiac readings. Optional enhancements such as a touch screen, advanced SpO2 measurements, and more are available to tailor its use according to specific medical needs. Whether monitoring heart rate with its impressive accuracy of ±3bpm or tracking SPO2 levels with ±2% precision, the YR02180 ensures reliable data delivery.
Market Price
When considering a purchase, understanding the market price range helps in making an informed decision. Similar high-quality fetal monitors typically range between $3,457 to $4,257 USD, providing prospective buyers with a competitive benchmark. Of course, actual pricing can vary depending on the specific configurations and optional features selected.
Frequently Asked Questions
- Is the YR02180 suitable for neonatal use? Yes, the monitor is equipped to handle adult, pediatric, and neonatal monitoring, with specific respiration rate settings for each group.
- Can the screen display multiple parameters simultaneously? Absolutely, the 17-inch LCD screen provides ample space to display multiple readings, ensuring comprehensive monitoring.
- Does the monitor offer wireless connectivity? While wireless capabilities are not standard, optional configurations may include enhanced connectivity features.
Advantages and Disadvantages
Advantages: The YR02180 stands out due to its modular design, extensive upgrade options, and precision in measuring vital parameters. Its versatility in different care settings makes it ideal for varied medical requirements.
Disadvantages: Some users may find the device’s complexity daunting without adequate training. Additionally, incorporating all available optional features can increase the overall cost.
Usage in the Field
In practical settings, the Doppler Fetal Monitor YR02180 is indispensable for real-time fetal and maternal monitoring in ICUs and surgical environments. Healthcare providers leverage its precise readings to make critical decisions, thanks to the device’s reliability in displaying accurate, up-to-the-second vital statistics.
Recommendations
To ensure optimal performance, regular calibration and maintenance of the YR02180 are recommended. It is also advised to stay updated on software upgrades which can enhance its functional capabilities. For inquiries or to generate a quotation, explore the convenient options available through the Kalstein Plus platform.
Features
- 17-inch LCD screen with semi-modular parameters
- Standard and optional advanced configurations
- Accurate ECG, SpO2, TEMP, NIBP, RESP, PR/HR monitoring
- Optional touch screen and enhanced SpO2 technologies
- Versatile use in ICU and OT environments
Technical Specifications
Model | YR02180 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Gain | x250, x500, x1000, x2000 | |
Accuracy | ±5% | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -1.0~+1.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 40~240bpm |
Accuracy | ±3bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 7~120BrPM | |
Neo/Ped | 7~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
NIBP
|
Method | Oscillometric |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm / 40~150bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~99% (±2%) | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |