Kalstein

LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675

SKU:YR05673 · By Kalstein

Category:Vertical autoclave

LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675

LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.

The LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675 stands out as a cutting-edge sterilization solution for healthcare facilities, including small clinics, expansive hospitals, and laboratories. Constructed from durable 304 stainless steel, this autoclave is built to last, providing excellent corrosion resistance and reinforcing a hygienic environment. Featuring an automated microprocessor control paired with an easy-to-read LCD display, users can effortlessly monitor key parameters such as temperature, pressure, time, and vacuum rate for a seamless sterilization process.

Market Price

In the competitive landscape of medical equipment, the Pulsating Vacuum Autoclave falls within a market price range of $7500 to $8600 USD. This pricing reflects the device's sophisticated technology and versatile features, making it a worthy investment for institutions with varied sterilization needs. Enhanced models, offering greater capacity and additional features like an independent steam generator, are particularly suited for environments with rigorous sterilization demands. For personalized pricing details, the Kalstein Plus platform streamlines request and quote generation, ensuring you receive an offer tailored to your specific requirements.

Frequently Asked Questions

  • What capacities are available for this autoclave?
The autoclave is available in three sizes: 50L, 80L, and 100L, catering to different sterilization volume requirements.
  • How user-friendly is the autoclave?
With its microprocessor control and LCD interface, the autoclave offers intuitive operation, clearly displaying the working status.

Advantages and Disadvantages

The Pulsating Vacuum Autoclave delivers impressive advantages, such as robust construction with 304 stainless steel for durability and effective corrosion resistance. The equipment's pulse vacuum drying system and built-in high-quality vacuum pump guarantee optimal sterilization. Conversely, the autoclave's substantial size and weight might restricted mobility in spaces with tight confines.

Product Use in the Field

Widely adopted in clinics, laboratories, and hospitals, this autoclave ensures the safe sterilization of medical instruments, textiles, rubber, and liquids. Its durable design and simplistic handling blend seamlessly into diverse environments, maintaining top-tier hygiene and safety standards across sterilization procedures.

Recommendations

To achieve peak performance, follow the manufacturer's guidance for maintaining the Pulsating Vacuum Autoclave. Routinely clean the sterilization chamber and verify the safety systems. Conduct functionality checks before each cycle to ensure consistent operation. Interested buyers can gather more information on specifications and pricing or request an automatic quote using the efficient Kalstein Plus platform, ensuring you secure the optimal autoclave for your sterilization needs.

Features

  • Advanced microprocessor control for easy operation.
  • LCD display for clear visualization of parameters.
  • Made from high-quality 304 stainless steel for durability.
  • Available in 50L, 80L, and 100L capacities.
  • Equipped with a built-in printer for cycle documentation.
  • Includes safety features like overheat and overpressure protection.

Technical Specifications

ModelYR05673YR05674YR05675
Max. pressure0.23Mpa
Working pressure0.22Mpa
Max. temperature136℃
Working temperature134℃
Working temperature range105 – 134℃
Vacuum rate-0.081Mpa
Sterilization time0 – 99 min
Drying time0 – 99 min
Accuracy of temperature0.1℃
Heat average≤± 1℃
TypeVertical Pulsating Vacuum Autoclave
ClassClass B
ControlMicroprocessor
DoorHand wheel type quick open door
DisplayLCD display
Drying systemVacuum drying
Vacuum pumpBuilt-in
Steam generatorBuilt-in
Sterilization programPre-set program + User-defined program + Test program
Water tankYes
PrinterYes
Sterilization basket2 PCS
LanguageEnglish
Voltage220-240V, 50/60Hz, single-phase
Chamber Size(mm)50L / Ø340×55080L / Ø420×600100L / Ø440×650
Outer Size(mm)660×460×1160700×520×1250700×520×1250
Packing Size(mm)820×600×1400820×620×1450820×620×1450
G.W. / N.W.120/100 kg172/142 kg176/146 kg

Technical specifications

ManufacturerKalstein

Video LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675

Frequently asked questions

How to know the prices of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?

To know the price of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675, please send us an email with your request through the contact form AQUI.

What are the delivery times for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for LCD Display Pulsating Vacuum Autoclave With Printer YR05673 // YR05675?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.