Kalstein

Förstå den operativa principen och vetenskapliga grunden för YR06054 Orbital Shaker

Av Kalstein · Publicerad:

Kategori:articulos-de-productos

Förstå den operativa principen och vetenskapliga grunden för YR06054 Orbital Shaker

Utforska de vetenskapliga principerna och operativa grunderna i YR06054 Orbital Shaker, inklusive designval och prestandaegenskaper.

3D available

Understanding the Operating Principle and Scientific Foundation of the YR06054 Orbital Shaker

The YR06054 Orbital Shaker is a sophisticated laboratory instrument designed for a range of applications, from sample homogenization to more complex procedures. This article will delve deep into the operating principles and the scientific foundation underlying the YR06054, ensuring that operators understand its functionality and capabilities.

Operating Principles of the YR06054 Orbital Shaker

The YR06054 operates on the principle of orbital shaking, which is characterized by the circular motion of its platform. This motion creates a uniform environment for the mixing of solutions and biological samples, allowing for consistent results.

The design choices of the YR06054, including its DC motor, ensure that the operation is both stable and quiet. The motor's specifications support a speed range of 40 to 200 rpm, which is adjustable via a digital control panel, allowing users to select the optimal speed for their specific application.

Key Features of the YR06054

  • Speed Range: 40-200 rpm
  • Load Capacity: Maximum 5 kg
  • Timing Range: 1 minute to 23 hours and 59 minutes
  • Plate Size: Available in 25 x 25 cm and 32 x 32 cm

Scientific Basis for the Design Choices

The YR06054's design is rooted in the need for efficient mixing and sample processing. The orbital shaking motion enhances the interaction between the sample and the surrounding environment, which is crucial for various scientific procedures.

The selection of a brushless DC motor contributes to the longevity and reliability of the device. The lack of brushes eliminates friction, allowing for smoother and quieter operation. This aspect is particularly important in sensitive laboratory environments where noise reduction is a priority.

Technical Specifications of the YR06054

ModelYR06054
Motor TypeDC Motor
Plate Size268 x 268 mm
Operation ModeCircular
Max Load2 kg
Speed Range40 - 200 rpm
Timing Range1 min - 19 h 59 min
DisplayLED Display
Power20 W
Voltage100-240 V, 50/60 Hz
Dimensions294 x 348 x 123 mm

Applications of the YR06054 in Laboratory Settings

The YR06054 Orbital Shaker is versatile and can be employed in various laboratory environments such as clinical, industrial, and educational settings. Each application benefits from its unique design features, allowing for tailored uses depending on specific requirements.

For instance, in a clinical laboratory, the YR06054 is essential for mixing samples to ensure homogeneity before analysis. In industrial laboratories, it can be used for quality control processes, while in educational settings, it serves as a teaching tool to demonstrate principles of fluid dynamics and mixing.

Common Issues and Troubleshooting the YR06054

While the YR06054 is designed for reliability, users may encounter issues that require troubleshooting. Common problems include the device not powering on, displaying error codes, or producing inconsistent results.

SymptomPossible CauseSolution
Device does not power onPower supply issueCheck power connections and ensure outlet is functioning.
Error code E-03Overload conditionRemove excess load and restart the device.
Inconsistent readingsImproper sample placementEnsure samples are evenly distributed on the platform.

Frequently Asked Questions

What is the maximum weight the YR06054 can handle?

The YR06054 Orbital Shaker has a maximum load capacity of up to 5 kg, making it suitable for mixing various laboratory samples.

How do I adjust the speed on the YR06054?

The speed can be adjusted via the digital control panel, allowing users to set the desired speed between 40 and 200 rpm based on their application needs.

What is the ideal temperature range for using the YR06054?

While the YR06054 is designed for laboratory environments, it is advisable to operate it within controlled temperature ranges, typically between 15°C and 30°C, to ensure optimal performance.

Can the YR06054 be used for cell culture?

Yes, the YR06054 is suitable for cell culture applications as it provides the gentle mixing required to maintain cell viability while ensuring adequate exposure to nutrients and gases.

Is the YR06054 easy to clean and maintain?

Yes, the YR06054 has a simple design that allows for easy cleaning. Regular maintenance involves checking the motor and ensuring that the platform is free from residues.

What kind of warranty does the YR06054 come with?

The YR06054 typically comes with a standard manufacturer warranty, covering any defects in materials and workmanship for a specified period. Please check with the supplier for specific warranty details.

How can I request a quote for the YR06054?

You can easily request a quote for the YR06054 by visiting our online portal or contacting our sales team directly for personalized assistance.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Orbital Shaker YR06054 with all specifications, dimensions, accessories and quote options.
View product datasheet →