Description
The YR01839 Online Conductivity Controller is an essential tool for industrial applications, offering precise monitoring of water conductivity and total dissolved solids (TDS). With a versatile 1 to 3 point calibration and 4 to 20 mA outputs, this controller stands out for its reliability and accuracy in ensuring optimal water quality management. Equipped with a platinum conductivity electrode and features like automatic temperature compensation, the YR01839 is designed to deliver consistent performance in variable conditions.
Market Price
The pricing for the YR01839 Online Conductivity Controller typically ranges between $400 and $600 on the market, depending on the vendor and additional accessory options. This competitive pricing makes it an accessible solution for small to medium-sized facilities looking to enhance their water quality monitoring systems.
Frequently Asked Questions
- What is the calibration process for the YR01839? The YR01839 supports 1 to 3 point calibration with automatic recognition of conductivity standards, ensuring easy and precise calibration procedures.
- Can this controller be used in high humidity environments? Yes, the device operates effectively in environments with relative humidity levels of less than 80%.
- Is the temperature compensation function automatic? Indeed, the YR01839 features automatic temperature compensation within a range of 0 to 100°C (32 to 212°F).
Advantages and Disadvantages
The YR01839 offers significant advantages including ease of calibration, selectable configuration settings, and a robust construction. Automatic features such as temperature compensation and factory reset enhance its user-friendliness. A potential downside is its lack of real-time wireless connectivity, which some users may prefer for remote monitoring.
Field Use
This controller is commonly used in water treatment plants, aquariums, and other settings where monitoring of water quality is critical. Its ability to provide precise conductivity and TDS measurements makes it a valuable asset for maintaining the desired standards of water purity and compliance with regulations.
Recommendations
To maximize the performance of your YR01839, regular calibration and maintenance are advised. Utilize the reset function to restore factory settings after significant changes, and ensure that the platinum electrode is routinely cleaned to prevent buildup that might affect measurements. For purchasing or to generate a quote, consider using our Kalstein Plus platform for ease and efficiency.
Features
- Inexpensive and reliable inline conductivity controller.
- Equipped with a platinum conductivity electrode.
- Automatic recognition of conductivity standards during calibration.
- Selectable cell constant, temperature coefficient, and TDS conversion factor.
- Automatic temperature compensation for precision across varying conditions.
- Configurable menu for calibration points, alarm limits, and output settings.
- Factory reset option for restoring default settings.
Technical Specifications
Model | YR01839 |
Conductivity | |
Range | 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution | 0.001, 0.01, 0.1, 1 |
Accuracy | ±1% F.S. |
Calibration Points | 1 to 3 points |
Calibration Solutions | 84uS, 1413uS, 12.88mS, 111.8mS |
TDS | |
Range | 0 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution | 0.01, 0.1, 1 |
Accuracy | ±1% F.S. |
TDS Factor | 0.1 to 1.0 (default 0.5) |
Temperature | |
Range | 0 to 100°C/32 to 212°F |
Resolution | 0.1°C/0.1°F |
Accuracy | ±1°C/±1.8°F |
Offset Calibration | 1 point |
Calibration Range | Reading ±10°C |
Communication | |
Signal Output | 4 to 20mA |
Load | Max. 500Ω |
Low or High Alarm | 0.02uS/cm to 20.0mS/cm, selectable |
Communication Interface | RS485 |
Connection Terminals | Detachable screw terminals |
General Specifications | |
Temperature Compensation | 0 to 100°C/32 to 212°F, automatic |
Temperature Coefficient | Linear (0.0 to 10.0%/°C) |
Reference Temperature | 25°C |
Cell Constant | K=0.1, 1, 10 |
Environmental Conditions | Ambient temperature <60°C, relative humidity <80% |
Power | DC24V |
Dimensions | 96(L)×96(W)×75(H)mm |
Weight | 350g |