The Benchtop Spectrophotometer YR05477 offers a high-precision solution for color measurement and analysis across a range of industrial and laboratory applications. With its advanced optical structures, such as reflective d/8 and transmissive d/0 geometry, this versatile device effectively measures both reflectance in objects and transmittance in liquids and transparent or translucent solids. Its compact design, coupled with a 7-inch TFT touch screen and LED and UV light sources, ensures user-friendly operation and consistent data reliability. Perfect for industries like plastics, textiles, paint, and cosmetics, the YR05477 is equipped with significant storage capabilities and sophisticated PC software to meet any color analysis needs.

Market Price

The Benchtop Spectrophotometer YR05477 is priced competitively within the range of $10,400 to $10,800 USD. This strategic investment facilitates enhanced precision and stability in quality control processes, making it stand out among other high-end spectrophotometers. For a custom quote that meets your industry-specific requirements, visit the Kalstein Plus platform to request a quote easily and quickly, with no obligations.

Frequently Asked Questions

  • Can the YR05477 handle both opaque and translucent samples? Absolutely, this model is built to measure both opaque and translucent materials, including liquids and transparent solids.
  • How much data can this spectrophotometer store? The YR05477 can store up to 20,000 test results, offering a thorough record for detailed analysis.
  • Does it allow for adjustable measurement apertures? Yes, you can choose from four apertures: φ25.4 mm, 15 mm, 8 mm, and 4 mm to suit different applications.

Advantages and Disadvantages

The YR05477 provides numerous advantages, including a temperature compensation system for precision in varied climates, the ability to measure in diverse color spaces, and an ergonomic design that supports prolonged use. However, users may find the need for periodic calibration in high-demand environments to uphold its accuracy as a potential downside.

Field Use

Designed for high-demand industries such as automotive, food, cosmetics, and medical sectors, where product appearance and color control are crucial, the YR05477 excels in measuring reflectance and transmittance across various materials. This capability makes it indispensable for quality control and product development labs, optimizing verification processes and ensuring compliance with quality standards at every production phase.

Recommendations

To ensure optimal performance of the YR05477, periodic calibration and maintaining the device in a stable and clean environment is advised. Adjusting the measurement aperture to the sample type and test conditions enhances accuracy and result consistency. Request your personalized quote today with Kalstein Plus and explore how the YR05477 Benchtop Spectrophotometer can revolutionize your quality control and color transfer processes, delivering precise and reliable measurements in every application.

Features

  • Advanced optical geometry: Reflective d/8 and transmissive d/0
  • 7-inch TFT touch screen for ease of use
  • Comprehensive illuminants with LED and UV light sources
  • Capacity to store up to 20,000 records
  • Versatile PC software included
  • Supports multiple color spaces and measurement apertures

Technical Specifications

ModelYR05477
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); SCI (specular component included)/SCE (specular component excluded); Include UV / excluded UV light source. Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing); SCI (specular component included)/SCE (specular component excluded); Include UV / excluded UV light source; Haze(ASTM D1003). Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicationIt is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing, etc industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Light Source360 nm to 780 nm, Combined LED Light, 400nm cut-off light source
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Interval10nm
Semiband Width10nm
Measured Reflectance Range0-200%
Measuring ApertureReflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25mm;
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE / Transmittance: SCI&SCE
Color SpaceCIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN Lab99
Color Difference FormulaΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1), ΔE * 00, DINΔE 99, ΔE (Hunter)
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle2°/10°
IlluminantD65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration). Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 (When a white calibration plate is measured 30 times at 5-second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
DimensionL*W*H=370x300x200mm
WeightApprox. 9.6kg
PowerAC 24V, 3A Power adapter power supply
Illuminant Life Span5 years, more than 3 million times measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data PortUSB & Print serial port
Data StorageStandard 2000 Pcs, Sample 20000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~50℃, 0~85%RH (no condensing)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
Optional AccessoryMicro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Technical specifications

DimensionsL 51 × W 45 × H 33 cm
Weight12.5 kg
ManufacturerKalstein

Video Benchtop Spectrophotometer YR05477

Frequently asked questions

How to know the prices of Benchtop Spectrophotometer YR05477?

To know the price of Benchtop Spectrophotometer YR05477, please send us an email with your request through the contact form AQUI.

What are the delivery times for Benchtop Spectrophotometer YR05477?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Benchtop Spectrophotometer YR05477?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Benchtop Spectrophotometer YR05477?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Benchtop Spectrophotometer YR05477?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.