Kalstein

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

SKU:YR05475 · By Kalstein

Category:Benchtop Spectrophotometer

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

Pulsed Xenon lamp Benchtop Spectrophotometer YR05475 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.

The Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 is a state-of-the-art tool designed by Kalstein for precise color and appearance analyses in laboratory and research environments. This device benefits from a pulsed xenon lamp, ensuring a longer service life and exceptional stability during measurements. It features a 7-inch TFT touchscreen and supports both reflective d/8 and transmissive d/0 optical geometries, with or without the UV component. The spectrophotometer's dual-array 256-element CMOS sensor and automatic aperture identification system (Φ25.4 mm, 8 mm, and 4 mm) guarantee highly accurate results across various sample types. This makes it ideal for tasks within R&D contexts where maintaining consistent and detailed outputs is crucial.

Market Price

The YR05475 spectrophotometer is priced competitively within the market, typically ranging from $3,445.00 to $4,245.00 USD. Despite its advanced capabilities, it remains a cost-effective option, especially for industries requiring precise quality control, such as plastics, paint, food, cosmetics, and medicine. To explore how this instrument can fit into your project's budget, take advantage of the Kalstein Plus platform to secure a personalized quote tailored to your specific industry needs.

Frequently Asked Questions

  • Can the YR05475 measure both translucent and opaque materials?
    Yes, it's designed to handle both opaque and translucent samples, including liquids and transparent solids.
  • How much data can the YR05475 store?
    This model can store up to 20,000 records, allowing for extensive testing data tracking.
  • Are the measurement apertures adjustable?
    Absolutely, the YR05475 offers three adjustable apertures (Φ25.4 mm, 8 mm, and 4 mm), providing analysis flexibility for different sample types.

Advantages and Disadvantages

The YR05475 offers numerous advantages, such as a temperature compensation system that delivers accurate results in varying environmental conditions and comprehensive lighting options (LED and UV). Its ergonomic design ensures ease of use in demanding environments. However, users may need to perform periodic calibrations in high-use scenarios to maintain peak accuracy.

Field Use

This spectrophotometer is particularly beneficial for quality control and product development laboratories across demanding industries like automotive, cosmetics, medical, and food sectors. Its capabilities in measuring reflectance and transmittance across diverse materials make it an essential tool for optimizing quality verification processes and ensuring high standards throughout production stages.

Recommendations

To ensure optimal performance and durability of the YR05475, regular calibrations and maintenance of the device in a clean, stable environment are recommended. Adjusting the measurement aperture based on the type of sample and specific testing conditions will further enhance accuracy and consistency. Don't miss out on transforming your quality control efforts—request your personalized quote through Kalstein Plus today!

Features

  • Pulsed xenon lamp for longevity and stability
  • Reflective d/8 and transmissive d/0 optical geometries
  • 256-element dual-array CMOS sensor
  • Automatic aperture identification system
  • Storage capacity for up to 20,000 records

Technical Specifications

ModelYR05475 (Pulsed xenon lamp)
Optical GeometryReflectance: d/8 (SCI⪰ Include UV/Exclude UV)
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003)
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Integrating Sphere SizeΦ 154mm
Light Source Device360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Pitch10nm
Semiband Width5nm
Reflectance Range0~200%
Measuring ApertureReflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE
Transmittance: SCI&SCE
Color SpaceCIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy
Color Difference FormulaΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99
Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle2° & 10°
IlluminantsD65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Displayed DataSpectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset
Measuring TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%)
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
Size370×300×200mm
WeightAbout 9.6kg
Power SupplyDC 24V, 3A Power Adapter
Light Source Device Life5 years, more than 3 million times measurements.
Display7″ TFT Capacitive Screen-touch Display
Data PortUSB & Print serial port
Data StorageStandard 2000 Pcs, Sample 20000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English,
Working EnvironmentTemperature: 0~40℃; Humidity: 0~85% (No Condensation)
Storage EnvironmentTemperature: -20~50℃; Humidity: 0~85% (No Condensation)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber,
Optional AccessoryMicro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Technical specifications

Weight12.5 kg
ManufacturerKalstein

Video Pulsed Xenon lamp Benchtop Spectrophotometer YR05475

Frequently asked questions

How to know the prices of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

To know the price of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475, please send us an email with your request through the contact form AQUI.

What are the delivery times for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.

How to make a purchase of Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.

How does the warranty work for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.

Can I request a quote online for Pulsed Xenon lamp Benchtop Spectrophotometer YR05475?

Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.